#1. What shall be the hanger rod sizes for a 10”-12” pipe size?

#2. A type of polymer used for grocery bags and food wraps.

#3. In constructing seepage pit, no brick or block shall be greater in height than its width and shall be laid flat to form at least a 101.6 mm wall

#4. What shall be the hanger rod sizes for a 5”-8” pipe size?

#5. Temporary workingmen facilities:

#6. It is a special joints from copper tubing to threaded pipe shall be made by the used of ?

#7. Required pressure tests exceeding 10 psi but less than 100 psi shall be performed with gauges of _____ incrementation or less.

#8. All trenches deeper than the footing of any building or structure and paralleling the same shall be at least?

#9. All brick or block used in seepage pit construction shall have a minimum compressive strength of ________.

#10. Solders and fluxes with lead content that exceeds ______ shall be prohibited in piping system used to convey potable water

#11. What shall be the hanger rod sizes for a ½”– 4” pipe size?

#12. Shall be used at all points of connection where there is a dissimilarity of metals in a special joints.

#13. Required pressure tests exceeding 100 psi shall be performed with gauges incremented for ____ or less of the required test pressure.

#14. A type of polymer used for detergents, milk bottles, oil containers and toys.

#15. All piping penetration of fire resistance related walls, partition, floors, floor/ceiling assemblies, roof/ceiling assemblies or shaft enclosures shall be protected in accordance of the Building Code and?

#16. Liquid temperature for brazing alloys shall be above?

#17. What will be the recommendation of a Master Plumber when the quantity of sewage exceeds the amount that can be disposed in 152.4 linear meter of each line in a disposal fields?

#18. The enlargement of a 3” closet bend or stub to 4” shall not be considered a/an?

#19. Trenches shall be backfilled in thin layers to _____ above the top of the piping with clean earth, which shall not contain stones, boulders, cinder-fill, frozen earth, construction debris or etc that would break the piping or cause corrosive action.

#20. Plastic pipe and fittings designed to be joined by solvent cementing shall comply with appropriate ______ Installation Standards

#21. A type of mechanical connection for joining copper tube that uses a crimping tool to affix the o-ring seal copper or copper alloy fitting to the tubing that is not permitted.

#22. Single-stack drainage and venting system with unvented branch line shall be?

#23. It is a trap seal protection for floor drain or similar traps connected to the drainage system except where not deemed necessary for safety or sanitation by Authority Having Jurisdiction?

#24. Sleeves shall not be required where openings are drilled or bored.

#25. Conventional pipe thread compounds, putty, linseed-oil-based products and unknown lubricants and sealants shall not be used on?